Raypak Repair Questions & Solutions, Tips & Guides Page 24 (2024)

  • Recent
  • Popular
  • Answered
  • Unanswered

0answers

Why do a get sensor failure message

Read full answer

Be the first to answer4/27/2016 3:07:55 AM •Raypak 2100 Pool...•Postedon Apr 27, 2016Be the first to answer

0answers

Raypak 2100 banging and shakes but stain onwhat is the problem

Read full answer

Be the first to answer4/27/2016 3:05:13 AM ••Postedon Apr 27, 2016Be the first to answer

0answers

How do fix a clogged or dirty filter?

Read full answer

Be the first to answer4/25/2016 4:04:49 AM •Raypak Rp2100...•Postedon Apr 25, 2016Be the first to answer

0answers

Model No P0131PCO/OD Heater ignites then flames out and then repeats this cycle ignites then goes out any ideas please

Read full answer

Be the first to answer4/11/2016 3:01:58 AM ••Postedon Apr 11, 2016Be the first to answer

0answers

Raypak boiler fire proofing broke off is it repairable?

Read full answer

Be the first to answer4/11/2016 2:49:13 AM ••Postedon Apr 11, 2016Be the first to answer

0answers

Whats it mean when it says remote control lockout?

Read full answer

Be the first to answer3/11/2016 11:49:33 PM •Raypak Rheem...•Postedon Mar 11, 2016Be the first to answer

0answers

Where can I find PIN to enter it when prompted?

Read full answer

Be the first to answer3/11/2016 11:21:51 PM •Raypak Rp2100...•Postedon Mar 11, 2016Be the first to answer

0helpful

1answer

Regarding my Raypak Spa Heater Versa 055B: Burner

I'm assuming, first, that your pump is running when you turn up the temp, otherwise, the high temp switch will turn off the gas. Then, it could be any of the switches hooked in series that must have flow thru them to let yhe ignition open the gas valve. ie could be water-flow switch not sensing enough eater running by it. Bypass (jumper) one at a time to find the culprit. Good luck...

Read full answer

2/6/2016 5:52:11 PM •Raypak Free...•Answeredon Feb 06, 2016

0answers

What does sw open mean on the digital display mean

Read full answer

Be the first to answer1/24/2016 2:27:33 AM •Raypak Rp2100...•Postedon Jan 24, 2016Be the first to answer

0answers

Blower motor wouldn't come on raypak natural gas heater

Read full answer

Be the first to answer1/24/2016 2:03:57 AM ••Postedon Jan 24, 2016Be the first to answer

0helpful

1answer

How do i fix the spark ignition for super ser F250 Catalytic gas heater ?

you should seriously consider getting a professional to change the ignition

Read full answer

1/12/2016 11:56:03 PM •Raypak Rp2100...•Answeredon Jan 12, 2016

0helpful

1answer

My service light is on, back of circuit board shows fault d20. What does that mean?

i believe that is a sensor fault. check the pressure switch

Read full answer

1/12/2016 11:43:49 PM •Raypak Rp2100...•Answeredon Jan 12, 2016

0helpful

1answer

Pool Not Heating Display Wrong

where the thermostat is located, the pump is not circulating the water

Read full answer

1/3/2016 5:17:17 AM •Raypak Free...•Answeredon Jan 03, 2016

0helpful

2answers

Rollout switch open displays

Fusible link or the Roll out switch are one and the same...if it burns out, or provides 'Open Circuit', then you had heat or flame exit the front of the heater instead of up!This is a problem that needs correction.Most common reason, Sooted Heat Exchanger / Tube Bundle.dissassemble and clean it - not with a brush!!!2nd possibility, especially if outdoor installation is a 'Downdraft'.Don't just replace rollout switch - FIX the reason it burned out!

Read full answer

11/16/2015 4:31:59 PM •Raypak Rp2100...•Answeredon Nov 16, 2015

0helpful

3answers

Pool heater Maintenance

Pool Heater Maintainance - Gas Pool HeaterGas heaters are the most common type of pool heaters being used presently. The gas heaters work on natural gas or propane tanks. The gas heaters are favorite hide out of spiders and other insects. It is recommended to regularly clean the spider webs and the debris off the heater. For it can clog off the burner openings. You can clean them manually or with the help of a vacuum cleaner as well.The most important thing about maintaining the gas pool heaters is to check the gas supply regularly. Check out the pipes to detect any leakages. You can easily detect the leakages using a soap solution. Prepare a liquid dish soap and warm water in the spray bottle. Now spray the solution on the pipe joints. If you find any bubbles emerging from the surface, you immediately need to repair the pipes. Never use the heater until the pipes are replaced or repaired by a qualified plumber.Pool Heater Maintainance - Electrical Pool HeaterElectrical pool heaters are also getting popular these days. The heaters produce the heat with the help of heating elements. The element can get coated with certain minerals present in the atmosphere. This hampers the heating process. You can easily take it out and clean with a wire brush. Some elements get damaged beyond repair. You have to replace the element. Take along the old element with you while looking around for a new one in the market.It is absolutely vital to change the element otherwise it can send some current in the swimming pool. First of all, turn off the power supply to the heater to avoid any injuries. Open up the drain pipe and take out water from it. Fix the new element and test the heater by filling water in your swimming pool so that the heater can work to its full efficiency.

Read full answer

9/10/2015 6:23:57 AM •Raypak DOOR...•Answeredon Sep 10, 2015

0helpful

1answer

Raypak 2100 milivolt gas knob won't turn from on to off

You'll have to replace the entire gas valve.

Read full answer

7/5/2015 11:04:30 PM ••Answeredon Jul 05, 2015

0helpful

1answer

Is there a way to purge air from the gas line?. Pilot won't light.

Yes, ventilate the room very good during and after the procedure. No Smoking.No electrical appliances within 10' should be On.Do not Turn on or off, any appliances, lights.This may cause a spark, that would not be good.Do not try to light heater after procedure... Wait 5 minutes.Now...Open the union and allow Fuel/Air to escape for 10 - 15 seconds. Re tighten union. Wait the suggested above to pass.blowing and venting room or area. now try to fire heater.if it worked, great. If not, repeat above procedure, until it does. If it doesn't, technical diagnostic required.

Read full answer

6/19/2015 7:04:04 AM •Raypak RP2100...•Answeredon Jun 19, 2015

0helpful

1answer

Need to replace heat sensor, where is it located on the unit?

there should be 3 heat sensors on the unit. Incoming water to decide if it needs heat, outgoing water, and a sensor on the burner(flame). the in and out sensor should be behind a panel near the inlet and outlet pipes. The burner sensor is more tricky usually near the igniter or below the heat exchanger inside the unit.Raypak Repair Questions & Solutions, Tips & Guides Page 24 (1)

Read full answer

6/18/2015 11:30:24 PM •Raypak Rp2100...•Answeredon Jun 18, 2015

0helpful

1answer

Why do I get CFH but then no SPK?

CFH = Call For HeatSPK = Ignitor is Sparking - attempting to ignite raw fuelIn a lot of cases, Pressure Switch opens up, CFH , is cancelled and therefor no ignition sequence.try cleaning filter really good. If cartridge, may be time for an overnight soak.

Read full answer

6/5/2015 1:28:29 PM •Raypak RP2100...•Answeredon Jun 05, 2015

0helpful

1answer

Reset water temp in pool

Up and down arrows on a digital unit will adjust temperature to higher or lower desired temperature.Potentiometer knob will adjust temp higher or lower by rotating the knob.My answer is only a guess at the question you are asking - no specifics, too general and too basic.

Read full answer

6/4/2015 2:02:52 PM •Raypak 266A...•Answeredon Jun 04, 2015

  • Prev
  • 1
  • ...
  • 22
  • 23
  • 24
  • 25
  • 26
  • Next

Not finding what you are looking for?
Raypak Repair Questions & Solutions, Tips & Guides Page 24 (2024)
Top Articles
Latest Posts
Article information

Author: Arline Emard IV

Last Updated:

Views: 5739

Rating: 4.1 / 5 (72 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Arline Emard IV

Birthday: 1996-07-10

Address: 8912 Hintz Shore, West Louie, AZ 69363-0747

Phone: +13454700762376

Job: Administration Technician

Hobby: Paintball, Horseback riding, Cycling, Running, Macrame, Playing musical instruments, Soapmaking

Introduction: My name is Arline Emard IV, I am a cheerful, gorgeous, colorful, joyous, excited, super, inquisitive person who loves writing and wants to share my knowledge and understanding with you.